Tricuspid valve replacement with mechanical versus biological prostheses: a systematic review and meta-analysis

Abstract

Background and objective

Tricuspid valve replacement (TVR) is required when repair is not feasible, and it continues to be a relatively high-risk procedure owing to the complex medical and/or surgical profile of patients. The choice between mechanical and biological prostheses for TVR remains a subject of debate owing to their distinct advantages and disadvantages. This study aimed to analyse and compare the clinical outcomes of these two types of prostheses in the tricuspid position.

Methods

PubMed, EMBASE, Web of Science, and the COCHRANE library were searched from 1995 to April 2023 for studies comparing clinical outcomes of mechanical versus biological valves in the tricuspid position. Data on 30-day mortality, reoperations, 5-year valve failure rates, thrombotic/thromboembolic events, and long-term survival were extracted, pooled, and analysed. Forest plots were generated using a random-effects model.

Results

From an initial pool of 4716 citations, 37 studies meeting our inclusion criteria were assessed, collectively encompassing 8316 prostheses (3796 mechanical, 4520 bioprostheses). Our analysis revealed that mechanical valves exhibited a non-significant trend towards diminished 30-day mortality (RR = 0.85, 95% CI = 0.69–1.06). A distinct disparity emerged in valve durability, with mechanical valves demonstrating a significantly increased risk of 5-year valve failure (RR = 2.21, 95% CI = 1.38–3.56). Strikingly, mechanical valves displayed a substantial six-fold elevated risk of thrombotic events (RR = 6.29, 95% CI = 3.98–9.92). In contrast, the long-term survival and reoperation rates demonstrated no statistically significant differences between the two valve types.

Conclusions

This systematic review and meta-analysis provides insights into the selection of mechanical and bioprosthetic valves for TVR. These findings highlight the potential advantages and disadvantages of mechanical and bioprosthetic valves in terms of early mortality, valve durability, and thrombotic risk. Our analysis provides clinicians with evidence-based guidance for optimizing outcomes in TVR, offering a foundation for informed decision-making in this intricate surgical landscape. Despite these insights, clinicians must overcome the limitations of retrospective studies, evolving healthcare, and anticoagulant disparities to ensure careful consideration in tricuspid valve replacement decisions.

Peer Review reports

Introduction

Tricuspid valve replacement (TVR) is considered a relatively infrequent surgical procedure, primarily reserved for patients presenting with significant structural or advanced functional issues within their tricuspid valve. Consequently, individuals undergoing TVR often exhibit a high-risk profile, with many having previously undergone tricuspid valve (TV) repair and experiencing complications such as right ventricular dysfunction [1]. Tricuspid valve replacement (TVR) is associated with elevated mortality and morbidity rates, with operative mortality ranging from 5 to 50% [2,3,4,5].

TV surgery has consistently posed formidable challenges [6,7,8,9,10,11,12,13,14]. When confronted with the decision to replace TV, the choice between mechanical and biological prostheses remains controversial. The implantation of mechanical valves theoretically carries an escalated risk of thromboembolic complications, particularly when the right ventricular function is less than normal. Conversely, bioprosthetic valves are susceptible to tissue degeneration and dysfunction, especially in the younger population and in pathological conditions characterized by progressive tissue infiltration and degeneration, such as carcinoid syndrome and end-stage renal disease. Additional complications related to anticoagulation within the mechanical valve group compared to the bioprosthetic group represent an additional challenge [15].

The principal objective of this meta-analysis was to compare the early and late outcomes among patients who have undergone TVR with either mechanical or biological prostheses. The resulting findings are anticipated to provide guidance to physicians and patients when making informed decisions regarding optimal valve selection for those undergoing TVR.

Materials and methods

This systematic review and meta-analysis was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines [16] (Supplementary Fig. 1).

Data sources and search strategy

A comprehensive literature search was performed in electronic databases including PubMed, Embase, Web of Science, and the Cochrane Library, from 1995 to April 2023. All relevant articles comparing the outcomes of mechanical and bioprosthetic tricuspid valves were retrieved. Only articles published in English were selected. Additional articles were manually identified by screening the reference lists of the obtained studies and similar clinical trials. Duplicate studies were eliminated using Endnote X7 (Clarivate Analytics, PA, USA). In cases where multiple studies by the same author or institution were conducted within a similar timeframe and reported comparable outcomes with the potential for overlap, only the most recent study was incorporated into this meta-analysis. A broad search strategy was employed to encompass the full breadth of articles using the following search string: “tricuspid valve replacement AND mechanical OR bioprosthetic”.

Study selection

The studies were deemed qualified for our systemic review and meta-analysis if they met the following requirements: (a) they were randomized controlled trials or observational studies (prospective or retrospective cohort or case–control studies); (b) they compared mechanical and biological valves; (c) their participants were adults only (including a paediatric population can introduce significant heterogeneity because of differences in their cardiovascular morphology physiology compared with adults); and (d) they evaluated at least one of the following predefined outcomes: 30-day mortality, reoperations/reinterventions, 5-year valve failure rates, thrombotic/thromboembolic events, and long-term survival. Studies with insufficient data, those with data not related to our prespecified objectives, letters and editorials, case reports, case series, or reviews were excluded.

Data extraction and quality assessment

Two independent researchers shortlisted the studies based on their titles and abstracts. The full texts of the remaining articles were thoroughly assessed. The results were compared side-by-side, and any discrepancies were resolved by a third researcher. The data extracted from the studies included study characteristics such as the first author’s surname, date of publication, total number of patients, number of patients in both groups, operative time range, and country of origin. The risk of bias was assessed using the Cochrane Risk of Bias in Non-randomized Studies of Interventions (ROBINS-I) tool [17].

Statistical analysis

Statistical analysis was performed using Review Manager, version 5.4 (Nordic Cochrane Center, Copenhagen, Denmark) and Comprehensive Meta-analysis Software (CMA). We pooled our results as risk ratios (RRs) with 95% confidence intervals (CIs) for 30-day mortality, 5-year valve failure, reoperation rate, and thrombotic and thromboembolic events, and hazard ratios (HRs) with 95% CIs for long-term survival using a random effects model. Forest plots were created to visually assess the results; a subgroup analysis was performed to differentiate the outcomes between studies using isolated TVR and TVR with concomitant procedures. Funnel plots, trim and fill sensitivity analysis, and Egger’s test were used to assess publication bias.

Results

Among the 4716 papers retrieved, 78 full-text articles were reviewed, and 37 were included in the final study cohort [1, 2, 5, 18,19,20,21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40,41,42,43,44,45,46,47,48,49,50,51] (Fig. 1). The analysis included 8380 prostheses, with 3860 (46.1%) being mechanical and 4520 (53.9%) being biological. The baseline characteristics, study design, and outcomes of the included studies are shown in Table 1. The analyses were performed to analyse the long-term outcomes of tricuspid valve replacement separately and with concomitant procedures such as atrial septal defect closures, arrhythmia surgery, pulmonary valvectomy, pulmonary valvotomy, repair of ruptured sinus of Valsalva, pericardiectomy, and coronary artery bypass graft.

Fig. 1
figure 1

PRISMA flow chart summarizing results of literature search. *Consider, if feasible to do so, reporting the number of records identified from each database or register searched (rather than the total number across all databases/registers). **If automation tools were used, indicate how many records were excluded by a human and how many were excluded by automation tools. From: Page MJ, McKenzie JE, Bossuyt PM, Boutron I, Hoffmann TC, Mulrow CD, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ 2021;372:n71. https://doiorg.publicaciones.saludcastillayleon.es/10.1136/bmj.n71. For more information, visit: http://www.prisma-statement.org/

Table 1 Baseline characteristics of the included studies

Long-term survival

A total of 26 studies reported long-term survival rates with follow-up to 20 years postoperatively; 11 studies reported long-term survival rates in the isolated TVR subgroup, of which two favoured bioprosthetic valves, while the remaining found no significant difference between the two valve types. Fifteen studies reported long-term survival rates in the TVR with concomitant procedures subgroup, of which only one study [33] favoured bioprosthetic valves, while others found no significant difference between the two types of valves. The pooled result did not reveal a significant difference between the two types of valves (HR = 1.09, 95% CI = 0.88–1.34, p = 0.43, I2 = 70%). To account for the substantial heterogeneity, we conducted a sensitivity analysis using the leave-one-out method, but the results remained non-significant (HR = 1.02, 95% CI = 0.87–1.20, I2 = 43%). (Fig. 2 and Supplementary Fig. 1a).

Fig. 2
figure 2

Long-term survival hazard ratio of each study with related 95% confidence limit

30-day mortality

16 studies reported 30-day mortality for isolated TVR, of which 3 favored mechanical valves, and 13 studies found no significant difference between the two valve types. 16 studies reported 30-day mortality of TVR with concomitant procedures, of which all showed no significant difference between the two. The meta-analysis found a pooled relative risk (RR) of 0.91 (95% CI = 0.62–1.34, p = 0.64, I2 = 60%) and 0.80 (95% CI = 0.64–1.00, p = 0.05, I2 = 12%) for isolated TVR and TVR with concomitant procedures, respectively, suggesting a 20% lower risk of mortality with mechanical valves when TVR is performed with concomitant procedure. (Fig. 3, Supplementary Fig. 1b).

Fig. 3
figure 3

Forest plot for 30-day mortality

5-year valve failure

6 studies reported 5-year valve failure of isolated TVR, of which 1 [38] favored bioprosthetic valves, while the remaining found no significant difference between the two valve types. 5 studies reported TVR with concomitant procedures, of which 1 study [1] favored bioprosthetic valves whereas the remaining found no significant difference between the outcome of the two valves. The results of the pooled studies were statistically significant, with a relative risk (RR) of 2.2 (95% CI = 1.38–3.56, p = 0.001, I2 = 0%) (Fig. 4). The results suggest that mechanical valves may be associated with an increased risk of valve failure at 5 years compared to bioprosthetic valves.

Fig. 4
figure 4

Forest plot of the 5-year valve failure

Reoperation

12 studies reported reoperation rate of isolated TVR, of which none showed a significant difference between the two types of valve. 10 studies reported reoperation rate of TVR with concomitant procedures, of which [29] favored mechanical valves, and [1] favored bioprosthetic valves, while the remaining showed no significant difference. The pooled risk ratio (RR) was 0.95 (95% CI = 0.69–1.32, p = 0.01, I2 = 45%) (Fig. 5).

Fig. 5
figure 5

Forest plot of reoperation

Thrombosis and thromboembolism

13 studies reported thrombosis and thromboembolism events in isolated TVR subgroup of which 5 favored bioprosthetic valve, and 11 studies reported thrombosis and thromboembolism events in TVR with concomitant procedures subgroup of which 4 favored bioprosthetic valve type, whereas the remaining studies in both subgroups showed no significant difference between the two types. The results of the pooled studies showed a relative risk (RR) of 6.67 (95% CI = 4.24–10.49), p = 0.00001, I2 = 0%) (Fig. 6). Data from the studies pooled in the meta-analysis indicate statistically significant results, suggesting a six-fold increased risk of thrombotic events with mechanical valves compared to biological prosthesis.

Fig. 6
figure 6

Forest plot for thrombosis and thromboembolism

Pacemaker insertion

Pacemaker insertion was reported in six studies, of which five were in the isolated TVR subgroup and one was in the TVR with concomitant procedures subgroup. In isolated TVR subgroup, 2 studies favored mechanical while other studies showed no significant difference between the two. The one study that reported TVR with concomitant procedures showed no significant difference. The result of the pooled studies showed a relative risk (RR) of 0.66 (95% CI = 0.48–0.90, p = 0.009, I2 = 0%) (Fig. 7). Data from the pooled results indicated a statistically significant difference in the risk of pacemaker insertion between the two types of valves, that is, patients receiving mechanical valves had a 34% lower risk of needing pacemaker insertion than those receiving bioprosthetic valves.

Fig. 7
figure 7

Forest plot for Pacemaker insertion

Publication bias

Examination of the funnel plot indicated some evidence of publication bias (Supplementary Fig. 2a–f). In addition to this potential bias, an Egger test was conducted to further assess the reliability of the results. Remarkably, the outcomes of the trim-and-fill sensitivity analysis demonstrated a minimal influence on the findings. A slight attenuation in the pooled risk ratio was observed, implying that the potential omission of studies would not significantly alter the overall conclusion. Furthermore, the trim-and-fill analysis estimated that a small number of studies might be missing from our meta-analysis due to publication bias; however, even considering these hypothetical studies, the overall effect remained relatively stable. These combined findings, along with the results of the Egger test, collectively suggest that the overall integrity of the analysis remains robust (Supplementary Fig. 3a–f,4a–f). However, it is important to acknowledge that while our analysis accounts for potential publication bias to some extent, the presence of such bias can introduce uncertainty in the interpretation of our results.

Risk of bias assessment

Using the ROBINS-I tool, 14 of the included studies were at high risk of bias—12 with risk of bias due to confounding, one with risk of bias due to missing data, and one with risk of bias both due to confounding and due to missing data. The remaining studies were judged to have a low risk of bias, but the full text of the study by Dalrymple-Hay et al. could not be assessed as the journal had been discontinued and the authors did not respond to our request for the manuscript.

Discussion

Current guidelines recommend TV surgery in cases of severe and progressive tricuspid regurgitation [52]. Repair is considered the intervention of choice and is superior to valve replacement [53]. TVR is indicated only in cases where TV repair is not feasible or has failed [54]. In such instances, the choice of bioprosthetic or mechanical valve is crucial and the subject of much controversy. The most recent meta-analysis on this subject was conducted by Cheng et al. [55]. However, the body of literature on this topic has grown significantly since that time. We conducted this systematic review and meta-analysis of thirty-seven studies to compare the short- and long-term surgical outcomes and complications associated with both valve types.

Our findings suggest no significant difference in long-term survival or reoperation rates associated with either type of valve. As TVR is used only in advanced cases, these findings can be explained by the poor survival rate of such patients regardless of the type of valve used [19]. Short-term mortality was also similar in both groups. These results suggest that both types of prostheses perform equally well. The comparable reoperation rates in both groups reinforce this argument. Our findings are similar to those of Cheng et al. [55].

We found a statistically significant difference in valve failure after five years. Our findings suggest that mechanical valves are more likely to fail than bioprosthetic valves, which is consistent with the findings of Cheng et al. [55]. The greater sample size of our analysis further reinforces this finding. We observed no heterogeneity between the studies, which increased the confidence in these findings. Subgroup analysis revealed no significant difference in case of isolated TVR, indicating that concomitant procedures might be responsible for the higher mechanical valve failure. Previously, mechanical aortic valves have been reported to cause more complications such as atrial fibrillation [56]. However, bioprosthetic valves are also prone to structural and non-structural problems, with the most critical causes of failure being calcification [57] and leaflet thickening [58]. There is variation in the failure rates of porcine and bovine valves. Calcification is more evident in bovine valves, whereas porcine valves are prone to tears and stenosis [59]. No studies have assessed bovine and porcine valves for tricuspid replacement.

Our most important finding is the exceptionally high rate of thrombotic and thromboembolic complications seen in mechanical valves compared to bioprosthetic valves. On the other hand, studies on aortic valves have shown twice the risk of cerebral and gastrointestinal bleeding with mechanical valves compared to bioprosthetic valves, highlighting the need for balanced anticoagulation therapy [60]. There was no heterogeneity among the studies, demonstrating the generalizability of these results. As our included studies did not mention the type of anticoagulation therapy administered after the procedure, future studies should explore the optimal anticoagulation therapy that minimizes the risk of thrombosis and bleeding.

Our results suggest an increased requirement for pacemaker insertion into biological valves. Previous studies did not have enough data for a meta-analysis of this outcome [61]. Previous studies involving the mitral and aortic valves have shown an increased incidence of atrioventricular block and pacemaker insertion [62, 63]. The conduction tissue is closely related to the TV, and TVR carries a high risk of trauma to the His bundle [64]. The reasons necessitating pacemaker insertion after TVR have not been studied previously and warrant further investigation.

Our findings should be interpreted in light of certain limitations. The included studies were mainly retrospective and observational, which may introduce confounding bias. The studies span a considerable time period, and the results of recent studies differ from those of older studies owing to advances in healthcare. The geographical distribution of our study is also quite broad, and these results may only apply to specific populations. Owing to their high cost, newer anticoagulant therapies are unavailable in many low-income countries. We could not analyse the difference in outcomes between primary TVR and reoperation because of a lack of data. Only a few studies included children, so we could not evaluate the benefits or risks of TVR in the paediatric population. Lastly, we observed unexplained heterogeneity in survival outcomes and reoperation rates. Additionally, it is important to consider the impact of publication bias, which may influence the representation of studies in our analysis. Although we have made efforts to assess and address this bias, its potential presence can introduce uncertainty in the interpretation of our findings.

Surgeons should consider patient demographics and medical history to lower the risk of thromboembolic complications. Studies have shown a lower mortality risk with TV surgery using the beating heart technique instead of cardioplegia [65]. Newly developed transcatheter approaches have shown promising results, but these techniques are still under investigation [66]. The optimal anticoagulation regimen, especially after mechanical valve insertion, should be comprehensively studied as mechanical valves are usually used in young patients. Future research should focus on randomized controlled trials to reduce confounding and to evaluate the safety profile of both prostheses and optimal adjunctive anticoagulant therapy, both in adults and in children. Bovine and porcine bioprosthetic valves should be compared and high-risk populations should be specifically monitored for adverse events. The effects of prior treatment, previous TV repair, reoperation with TVR, and concomitant procedures on long-term outcomes should be addressed.

Conclusion

Our systematic review and meta-analysis compared bioprosthetic and mechanical valves for tricuspid valve replacement. A key finding of our meta-analysis was that mechanical valves had a six-fold higher risk of thrombotic and thromboembolic complications. Furthermore, the incidence of five-year-valve failure and pacemaker insertion were found to be reduced with the bioprosthetic valves. No significant difference was found in long-term survival and 30-day mortality between the two types of valves. Bioprosthetic valves are associated with an increased requirement for pacemaker insertion. Surgeons should consider patient demographics and medical history when selecting the appropriate valve type.

Availability of data and materials

Data and materials can be obtained by contacting the corresponding author.

References

  1. Albacker TB, Arafat AA, Alotaibi AM, Alghosoon H, Algarni KD. Mechanical tricuspid valves have higher rate of reintervention: a single center experience. Ann Thorac Cardiovasc Surg. 2023;29(2):22–00086.

    Article  Google Scholar 

  2. Iscan ZH, Vural KM, Bahar I, Mavioglu L, Saritas A. What to expect after tricuspid valve replacement? Long-term results. Eur J Cardiothorac Surg. 2007;32(2):296–300.

    Article  PubMed  Google Scholar 

  3. Van Nooten GJ, Caes F, Taeymans Y, Van Belleghem Y, François K, De Bacquer D, et al. Tricuspid valve replacement: Postoperative and long-term results. J Thorac Cardiovasc Surg. 1995;110(3):672–9.

    Article  PubMed  Google Scholar 

  4. Mangoni AA, DiSalvo TG, Vlahakes GJ, Polanczyk CA, Fifer MA. Outcome following isolated tricuspid valve replacement. Eur J Cardiothorac Surg. 2001;19(1):68–73.

    Article  CAS  PubMed  Google Scholar 

  5. Filsoufi F, Anyanwu AC, Salzberg SP, Frankel T, Cohn LH, Adams DH. Long-term outcomes of tricuspid valve replacement in the current era. Ann Thorac Surg. 2005;80(3):845–50.

    Article  PubMed  Google Scholar 

  6. Grondin P. The tricuspid valve: A surgical challenge

  7. Braunwald NS, Ross J, Morrow AG. Conservative Management of Tricuspid Regurgitation in Patients Undergoing Mitral Valve Replacement. Circulation. 1967;35(4s1):1–63.

    Article  Google Scholar 

  8. Baughman KL, Kallman CH, Yurchak PM, Daggett WM, Buckley MJ. Predictors of survival after tricuspid valve surgery. Am J Cardiol. 1984;54(1):137–41.

    Article  CAS  PubMed  Google Scholar 

  9. Kaul T, Mercer J. Tricuspid valve replacement: factors influencing early and late mortality. Thorac Cardiovasc Surg. 1990;38(04):229–35.

    Article  CAS  PubMed  Google Scholar 

  10. Hauck AJ, Freeman DP, Ackermann DM, Danielson GK, Edwards WD. Surgical pathology of the tricuspid valve: a study of 363 cases spanning 25 years. Mayo Clin Proc. 1988;63(9):851–63.

    Article  CAS  PubMed  Google Scholar 

  11. Pluth JR, Henry EF. Tricuspid insufficiency in patients undergoing mitral valve replacement. J Thorac Cardiovasc Surg. 1969;58(4):484–91.

    Article  Google Scholar 

  12. Cohen SR, Sell JE, McIntosh CL, Clark RE. Tricuspid regurgitation in patients with acquired, chronic, pure mitral regurgitation. II. Nonoperative management, tricuspid valve annuloplasty, and tricuspid valve replacement. J Thorac Cardiovasc Surg. 1987;94(4):488–97.

    Article  CAS  PubMed  Google Scholar 

  13. McGrath LB, Gonzalez-Lavin L, Bailey BM, Grunkemeier GL, Fernandez J, Laub GW. Tricuspid valve operations in 530 patients. Twenty-five-year assessment of early and late phase events. J Thorac Cardiovasc Surg. 1990;99(1):124–33.

    Article  CAS  PubMed  Google Scholar 

  14. Kay GL, Morita S, Mendez M, Zubiate P, Kay JH. Tricuspid regurgitation associated with mitral valve disease: Repair and replacement. Ann Thorac Surg. 1989;48(3):S93–5.

    Article  CAS  PubMed  Google Scholar 

  15. Shahmohamadi E, Hadizadeh A, Ayati A, Tayebi A, Ahmadi Tafti SH, Abbasi K, et al. Evaluation of risk factors and outcomes of isolated tricuspid valve replacement with a conventional surgical approach: a retrospective cohort study. J Card Surg. 2023;9(2023):1–5.

    Article  Google Scholar 

  16. Phan K, Tian DH, Cao C, Black D, Yan TD. Systematic review and meta-analysis: techniques and a guide for the academic surgeon. Ann Cardiothorac Surg. 2015;4(2):112–22.

    PubMed  PubMed Central  Google Scholar 

  17. Sterne, J. A. C., Hernán, M. A., Reeves, B. C., Savović, J., Berkman, N. D., Viswanathan, M., Henry, D., Altman, D. G., Ansari, M. T., Boutron, I., Carpenter, J. R., Chan, A.-W., Churchill, R., Deeks, J. J., Hróbjartsson, A., Kirkham, J., Jüni, P., Loke, Y. K., Pigott, T. D., … Higgins, J. P. T. (2016). ROBINS-I: a tool for assessing risk of bias in non-randomised studies of interventions. BMJ (Clinical Research Ed.), 355, i4919. https://doiorg.publicaciones.saludcastillayleon.es/10.1136/bmj.i4919

  18. Ian Munro A, Eric Jamieson WR, Frank G, Tyers O, Germann E. Tricuspid valve replacement: Porcine bioprostheses and mechanical prostheses. Ann Thorac Surg. 1995;60:S470–4.

    Article  Google Scholar 

  19. Scully HE, Armstrong CS. Tricuspid valve replacement: Fifteen years of experience with mechanical prostheses and bioprostheses. J Thorac Cardiovasc Surg. 1995;109(6):1035–41.

    Article  CAS  PubMed  Google Scholar 

  20. Vannooten G, Caes F, Francois K, Taeymans Y, Primo G, Wellens F, et al. The valve choice in tricuspid valve replacement: 25 years of experience. Eur J Cardiothorac Surg. 1995;9(8):441–7.

    Article  CAS  Google Scholar 

  21. Hayashi J, Saito A, Yamamoto K, Watanabe H, Ohzeki H, Eguchi S. Is a bioprosthesis preferable in tricuspid valve replacement? Thorac Cardiovasc Surg. 1996;44(05):230–3.

    Article  CAS  PubMed  Google Scholar 

  22. Rizzoli G, De Perini L, Bottio T, Minutolo G, Thiene G, Casarotto D. Prosthetic replacement of the tricuspid valve: biological or mechanical? Ann Thorac Surg. 1998;66(6):S62–7.

    Article  CAS  PubMed  Google Scholar 

  23. Ratnatunga CP, Edwards MB, Dore CJ, Taylor KM. Tricuspid valve replacement: UK heart valve registry mid-term results comparing mechanical and biological prostheses. Ann Thorac Surg. 1998;66(6):1940–7.

    Article  CAS  PubMed  Google Scholar 

  24. Dalrymple-Hay MJ, Leung Y, Ohri SK, Haw MP, Ross JK, Livesey SA, et al. Tricuspid valve replacement: bioprostheses are preferable. J Heart Valve Dis. 1999;8(6):644–8.

    CAS  PubMed  Google Scholar 

  25. Kaplan M, Kut MS, Demirtas MM, Cimen S, Ozler A. Prosthetic replacement of tricuspid valve: bioprosthetic or mechanical. Ann Thorac Surg. 2002;73(2):467–73.

    Article  PubMed  Google Scholar 

  26. Solomon NAG, Lim RCH, Nand P, Graham KJ. Tricuspid valve replacement: bioprosthetic or mechanical valve? Asian Cardiovasc Thorac Ann. 2004;12(2):143–8.

    Article  PubMed  Google Scholar 

  27. Rizzoli G, Vendramin I, Nesseris G, Bottio T, Guglielmi C, Schiavon L. Biological or mechanical prostheses in tricuspid position? A meta-analysis of intra-institutional results. Ann Thorac Surg. 2004;77(5):1607–14.

    Article  PubMed  Google Scholar 

  28. Carrier M, Hébert Y, Pellerin M, Bouchard D, Perrault LP, Cartier R, et al. Tricuspid valve replacement: an analysis of 25 years of experience at a single center. Ann Thorac Surg. 2003;75(1):47–50.

    Article  PubMed  Google Scholar 

  29. Chang BC, Lim SH, Yi G, Hong YS, Lee S, Yoo KJ, et al. Long-Term clinical results of tricuspid valve replacement. Ann Thorac Surg. 2006;81(4):1317–24.

    Article  PubMed  Google Scholar 

  30. Civelek A, Ak K, Akgün S, Isbir S, Arsan S. Tricuspid valve replacement: an analysis of risk factors and outcomes. Thorac Cardiovasc Surg. 2008;56(08):456–60.

    Article  CAS  PubMed  Google Scholar 

  31. Tokunaga S, Tominaga R. Current status of the mechanical valve and bioprosthesis in Japan. J Artif Organs. 2008;11(2):53–9.

    Article  PubMed  Google Scholar 

  32. Moraca RJ, Moon MR, Lawton JS, Guthrie TJ, Aubuchon KA, Moazami N, et al. Outcomes of tricuspid valve repair and replacement: a propensity analysis. Ann Thorac Surg. 2009;87(1):83–9.

    Article  PubMed  Google Scholar 

  33. Brown ML, Dearani JA, Danielson GK, Cetta F, Connolly HM, Warnes CA, et al. Comparison of the outcome of porcine bioprosthetic versus mechanical prosthetic replacement of the tricuspid valve in the ebstein anomaly. Am J Cardiol. 2009;103(4):555–61.

    Article  PubMed  Google Scholar 

  34. Sung K, Park PW, Park KH, Jun TG, Lee YT, Yang JH, et al. Is tricuspid valve replacement a catastrophic operation? Eur J Cardiothorac Surg. 2009;36(5):825–9.

    Article  PubMed  Google Scholar 

  35. Garatti A, Nano G, Bruschi G, Canziani A, Colombo T, Frigiola A, et al. Twenty-Five year outcomes of tricuspid valve replacement comparing mechanical and biologic prostheses. Ann Thorac Surg. 2012;93(4):1146–53.

    Article  PubMed  Google Scholar 

  36. Hwang HY, Kim KH, Kim KB, Ahn H. Mechanical tricuspid valve replacement is not superior in patients younger than 65 years who need long-term anticoagulation. Ann Thorac Surg. 2012;93(4):1154–60.

    Article  PubMed  Google Scholar 

  37. Cho WC, Bin PC, Kim JB, Jung SH, Chung CH, Choo SJ, et al. Mechanical valve replacement versus bioprosthetic valve replacement in the tricuspid valve position. J Card Surg. 2013;28(3):212–7.

    Article  PubMed  Google Scholar 

  38. Altaani HA, Jaber S. Tricuspid valve replacement, mechnical vs. biological valve, which is better? Int Cardiovasc Res J. 2013;7(2):71–4.

    PubMed  PubMed Central  Google Scholar 

  39. Kim JB, Jung SH, Choo SJ, Chung CH, Lee JW. Clinical and echocardiographic outcomes after surgery for severe isolated tricuspid regurgitation. J Thorac Cardiovasc Surg. 2013;146(2):278–84.

    Article  PubMed  Google Scholar 

  40. Rodríguez-Capitán J, Gómez-Doblas JJ, Fernández-López L, López-Salguero R, Ruiz M, Leruite I, et al. Short- and long-term outcomes of surgery for severe tricuspid regurgitation. Revista Española de Cardiología (English Edition). 2013;66(8):629–35.

    Article  Google Scholar 

  41. Hwang HY, Kim KH, Kim KB, Ahn H. Propensity score matching analysis of mechanical versus bioprosthetic tricuspid valve replacements. Ann Thorac Surg. 2014;97(4):1294–9.

    Article  PubMed  Google Scholar 

  42. Songur CM, Simsek E, Ozen A, Kocabeyoglu S, Donmez TA. Long term results comparing mechanical and biological prostheses in the tricuspid valve position. Heart Lung Circ. 2014;23(12):1175–8.

    Article  PubMed  Google Scholar 

  43. Connolly HM, Schaff HV, Abel MD, Rubin J, Askew JW, Li Z, et al. Early and late outcomes of surgical treatment in carcinoid heart disease. J Am Coll Cardiol. 2015;66(20):2189–96.

    Article  PubMed  Google Scholar 

  44. Anselmi A, Ruggieri VG, Harmouche M, Flécher E, Corbineau H, Langanay T, et al. Appraisal of Long-term outcomes of tricuspid valve replacement in the current perspective. Ann Thorac Surg. 2016;101(3):863–71.

    Article  PubMed  Google Scholar 

  45. Redondo Palacios A, López Menéndez J, Miguelena Hycka J, Martín García M, Varela Barca L, Ferreiro Marzal A, et al. Which type of valve should we use in tricuspid position? Long-term comparison between mechanical and biological valves. J Cardiovasc Surg (Torino). 2017;58(5):739–46.

    PubMed  Google Scholar 

  46. Chen SW, Wu VCC, Lin YS, Chen CC, Chen DY, Chang CH, et al. Propensity score matched analysis of mechanical vs. bioprosthetic valve replacement in patients with previous stroke. Circ J. 2018;82(8):2041–8.

    Article  PubMed  Google Scholar 

  47. Wiedemann D, Rupprechter V, Mascherbauer J, Kammerlander A, Mora B, Dimitrov K, et al. Tricuspid valve replacement: results of an orphan procedure - which is the best prosthesis? J Cardiovasc Surg (Torino). 2018;59(4):626–6324.

    PubMed  Google Scholar 

  48. Liang W. The better substitute for tricuspid valve replacement in patients with severe isolated tricuspid regurgitation. The Anatolian Journal of Cardiology. 2019;22(4):172–6.

    PubMed  Google Scholar 

  49. Kang Y, Hwang HY, Sohn SH, Choi JW, Kim KH, Kim KB. Fifteen-year outcomes after bioprosthetic and mechanical tricuspid valve replacement. Ann Thorac Surg. 2020;110(5):1564–71.

    Article  PubMed  Google Scholar 

  50. Patlolla SH, Saran N, Schaff HV, Crestanello J, Pochettino A, Stulak JM, et al. Prosthesis choice for tricuspid valve replacement: Comparison of clinical and echocardiographic outcomes. J Thorac Cardiovasc Surg. 2022;167(2):668–79.

    Article  PubMed  Google Scholar 

  51. Sohn SH, Kang Y, Kim JS, Hwang HY, Kim KH, Choi JW. Early and long-term outcomes of bioprosthetic versus mechanical tricuspid valve replacement: a nationwide population-based study. J Thorac Cardiovasc Surg. 2023;167(6):2117–28.

    Article  PubMed  Google Scholar 

  52. Otto CM, Nishimura RA, Bonow RO, Carabello BA, Erwin JP, Gentile F, et al. 2020 ACC/AHA guideline for the management of patients with valvular heart disease: executive summary: a report of the american college of cardiology/American heart association joint committee on clinical practice guidelines. J Am Coll Cardiol. 2021;77(4):450–500.

    Article  PubMed  Google Scholar 

  53. Choi JW, Jin JM, Kim KH, Hwang HY. Repair versus replacement for the surgical correction of tricuspid regurgitation: a meta-analysis. Eur J Cardio-Thorac Surg. 2018;53(4):748–55.

    Article  Google Scholar 

  54. Dreyfus J, Dreyfus GD, Taramasso M. Tricuspid valve replacement: The old and the new. Prog Cardiovasc Dis. 2022;72:102–13.

    Article  PubMed  Google Scholar 

  55. Cheng Z, Fang T, Wang D, Guo Y. Tricuspid valve replacement: mechanical or biological prostheses? A systematic review and meta-analysis. Heart Surg Forum. 2021;24(2):E209–14.

    Article  PubMed  Google Scholar 

  56. Bozso SJ, White A, Kang JJ, Hong Y, Norris CM, Lakey O, MacArthur RG, Nagendran J, Nagendran J, Moon MC. Long-term outcomes following mechanical or bioprosthetic aortic valve replacement in young women. CJC open. 2020;2(6):514–21.

    Article  PubMed  PubMed Central  Google Scholar 

  57. Koziarz A, Makhdoum A, Butany J, Ouzounian M, Chung J. Modes of bioprosthetic valve failure: a narrative review. Curr Opin Cardiol. 2020;35(2):123–32.

    Article  PubMed  Google Scholar 

  58. Case BC, Khan JM, Rogers T. Early leaflet thickening, durability and bioprosthetic valve failure in TAVR. Interv Cardiol Clin. 2021;10(4):531–9.

    PubMed  PubMed Central  Google Scholar 

  59. Keshishi M, Fatima R, Seidman MA, Butany J, Ouzounian M, Chung J. Comparison of modes of failure and clinical outcomes between explanted porcine and bovine pericardial bioprosthetic valves. Cardiovasc Pathol. 2023;65: 107516.

    Article  CAS  PubMed  Google Scholar 

  60. Matsuura K, Yamamoto H, Miyata H, Matsumiya G, Motomura N. Mechanical vs bioprosthetic aortic valve replacement in patients on dialysis: long-term outcomes. Ann Thorac Surg. 2023;116(1):61–7.

    Article  PubMed  Google Scholar 

  61. Negm S, Arafat AA, Elatafy EE, Fawzy HF. Mechanical versus bioprosthetic valve replacement in the tricuspid valve position: a systematic review and meta-analysis. Heart Lung Circ. 2021;30(3):362–71.

    Article  PubMed  Google Scholar 

  62. Herrmann FEM, Schleith AS, Graf H, Sadoni S, Hagl C, Bagaev E, et al. Tricuspid valve annuloplasty and mitral valve replacement are associated with bradyarrhythmia after mitral valve surgery. J Cardiovasc Electrophysiol. 2021;32(4):1103–10.

    Article  PubMed  Google Scholar 

  63. Sammour Y, Krishnaswamy A, Kumar A, Puri R, Tarakji KG, Bazarbashi N, et al. Incidence, predictors, and implications of permanent pacemaker requirement after transcatheter aortic valve replacement. JACC Cardiovasc Interv. 2021;14(2):115–34.

    Article  PubMed  Google Scholar 

  64. Bazire B, Algalarrondo V, Dreyfus J. Permanent pacemaker implantation after tricuspid valve surgery. Case Rep. 2023;3(13): 101805.

    Google Scholar 

  65. Russo M, Di Mauro M, Saitto G, Lio A, Berretta P, Taramasso M, et al. Beating versus arrested heart isolated tricuspid valve surgery: long-term outcomes. Ann Thorac Surg. 2022;113(2):585–92.

    Article  PubMed  Google Scholar 

  66. Greenbaum AB, Babaliaros VC, Eng MH. Orthotopic transcatheter tricuspid valve replacement. Interv Cardiol Clin. 2022;11(1):87–94.

    PubMed  Google Scholar 

Download references

Funding

None available.

Author information

Authors and Affiliations

Authors

Contributions

Muhammad Abdul Qadeer Conceptualization, Formal analysis, Methodology, Project administration, Software, Supervision, Validation, Visualization, Writing – original draft, Writing – review & editing Ali Abdullah Formal analysis, Methodology, Software, Validation, Visualization Amber Noorani Conceptualization, Methodology, Project administration, Supervision, Validation, Writing – original draft Abdul Hadi Khan Writing – original draft Muhammad Saqlain Mustafa Validation, Writing – original draft, Writing – review & editing Zain Ali Nadeem Project administration, Validation, Writing – original draft, Writing – review & editing Shahzaib Samad Formal analysis, Software, Visualization, Writing – original draft Muhammad Usama Siddiq Writing – original draft Rabeeya Qutub Uddin Data curation, Writing – original draft Sameh M. Said Project administration, Supervision, Validation, Writing – review & editing.

Corresponding author

Correspondence to Sameh M. Said.

Ethics declarations

Ethics approval and consent to participate

Not Applicable.

Competing interests

The author Sameh M. Said is a consultant for Artivion, Abbott, and JOMDD.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc-nd/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Abdul Qadeer, M., Abdullah, A., Noorani, A. et al. Tricuspid valve replacement with mechanical versus biological prostheses: a systematic review and meta-analysis. J Cardiothorac Surg 19, 636 (2024). https://doiorg.publicaciones.saludcastillayleon.es/10.1186/s13019-024-03014-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doiorg.publicaciones.saludcastillayleon.es/10.1186/s13019-024-03014-0

Keywords